Search found 85 matches

by lollette
Sat Aug 24, 2019 2:17 am
Forum: CNC
Topic: nvem no kind out1 a out10 does not work on my card it is the solution
Replies: 0
Views: 7426

nvem no kind out1 a out10 does not work on my card it is the solution

1. If it used to work properly, this point is broken.
2. If you haven't used it, it's a setup problem.
1. S'il travaillait correctement, ce point est cassé.
2. Si vous ne l'avez pas utilisé, c'est un problème d'installation.
by lollette
Tue Aug 20, 2019 6:16 am
Forum: PLC & HMI
Topic: OP230 connection problem
Replies: 4
Views: 5580

Re: OP230 connection problem

Yes, you are correct - I was counting the pins from the wrong end. I have connected as you have indicated and I now have communication working successfully. Thank you for your help. It is worth mentioning that your OP230 manual shows the connections differently, as per the following diagram. This is...
by lollette
Tue Aug 20, 2019 6:16 am
Forum: PLC & HMI
Topic: OP230 connection problem
Replies: 4
Views: 5580

Re: OP230 connection problem

no , it is. 8-b , 9-a
by lollette
Tue Aug 20, 2019 6:16 am
Forum: PLC & HMI
Topic: OP230 connection problem
Replies: 4
Views: 5580

Re: OP230 connection problem

Thank you for this information. From the video, it looks like the pins used on the D9 serial port are



6 = RS485-A

7 = RS485-B

9 connected to 5 (GND)



Could you please confirm if this is correct. This is very different to your documentation on the OP230AS.
by lollette
Tue Aug 20, 2019 6:15 am
Forum: PLC & HMI
Topic: OP230 connection problem
Replies: 4
Views: 5580

Re: OP230 connection problem

here is setting. op320 with le3u plc. by rs485

https://youtu.be/meQsBhmFxMI
by lollette
Tue Aug 20, 2019 6:15 am
Forum: PLC & HMI
Topic: OP230 connection problem
Replies: 4
Views: 5580

OP230 connection problem

Hi Team Lollette. I am looking for technical support with a connection issue with your OP230-A&S operator panel. I have successful used these many time in the past connecting to Mitsubishi PLC, however I am now trying to connect to a different controller using Modbus RTU protocol. I can see the Modb...
by lollette
Tue Aug 20, 2019 2:37 am
Forum: PLC & HMI
Topic: LE3U PLC with Kinco ET100
Replies: 5
Views: 6349

Re: LE3U PLC with Kinco ET100

hello,

AT last I found the solution !!!!!!!!!!
It seems to be a problem with the V2.2 software from Kinco
I downloaded version V2.5... and now it works fine!!

This info is also interesting to know on your part? ..

Best regards
by lollette
Tue Aug 20, 2019 2:36 am
Forum: PLC & HMI
Topic: LE3U PLC with Kinco ET100
Replies: 5
Views: 6349

Re: LE3U PLC with Kinco ET100

Hello I just tested, no solution. When i choose FX2N, there is no communication. I tried all Mitsubishi setting, the only one that works is FX3U, but the refresh rate is too long, only a action of feedback update every 10 to15 seconds. Can your do this test over at your lab? Enclosed a video how slo...
by lollette
Tue Aug 20, 2019 2:36 am
Forum: PLC & HMI
Topic: LE3U PLC with Kinco ET100
Replies: 5
Views: 6349

Re: LE3U PLC with Kinco ET100

YES, I just let you see setting , choose fx2n.
by lollette
Tue Aug 20, 2019 2:36 am
Forum: PLC & HMI
Topic: LE3U PLC with Kinco ET100
Replies: 5
Views: 6349

Re: LE3U PLC with Kinco ET100

Hello Thx for the reply.. I watched the video, clear, this is also what I have done As you see in my mail, I set the correct speed in the Kinco HMI for this FX3U module, (RS232, 38400Bd) It seems to communicate, (because com error disappears from screen) but very slow.. 10 to 15 sec. updates?? Ok, i...